672 research outputs found
Analysis of a distributed fiber-optic temperature sensor using single-photon detectors
We demonstrate a high-accuracy distributed fiber-optic temperature sensor using superconducting nanowire single-photon detectors and single-photon counting techniques. Our demonstration uses inexpensive single-mode fiber at standard telecommunications wavelengths as the sensing fiber, which enables extremely low-loss experiments and compatibility with existing fiber networks. We show that the uncertainty of the temperature measurement decreases with longer integration periods, but is ultimately limited by the calibration uncertainty. Temperature uncertainty on the order of 3 K is possible with spatial resolution of the order of 1 cm and integration period as small as 60 seconds. Also, we show that the measurement is subject to systematic uncertainties, such as polarization fading, which can be reduced with a polarization diversity receiver
Fast path and polarisation manipulation of telecom wavelength single photons in lithium niobate waveguide devices
We demonstrate fast polarisation and path control of photons at 1550 nm in
lithium niobate waveguide devices using the electro-optic effect. We show
heralded single photon state engineering, quantum interference, fast state
preparation of two entangled photons and feedback control of quantum
interference. These results point the way to a single platform that will enable
the integration of nonlinear single photon sources and fast reconfigurable
circuits for future photonic quantum information science and technology.Comment: 6 page
Nano-optical observation of cascade switching in a parallel superconducting nanowire single photon detector
The device physics of parallel-wire superconducting nanowire single photon
detectors is based on a cascade process. Using nano-optical techniques and a
parallel wire device with spatially-separate pixels we explicitly demonstrate
the single- and multi-photon triggering regimes. We develop a model for
describing efficiency of a detector operating in the arm-trigger regime. We
investigate the timing response of the detector when illuminating a single
pixel and two pixels. We see a change in the active area of the detector
between the two regimes and find the two-pixel trigger regime to have a faster
timing response than the one-pixel regime.Comment: 11 pages, 2 figure
Long gravitational-wave transients and associated detection strategies for a network of terrestrial interferometers
Searches for gravitational waves (GWs) traditionally focus on persistent sources (e.g., pulsars or the stochastic background) or on transients sources (e.g., compact binary inspirals or core-collapse supernovae), which last for time scales of milliseconds to seconds. We explore the possibility of long GW transients with unknown waveforms lasting from many seconds to weeks. We propose a novel analysis technique to bridge the gap between short O(s) “burst” analyses and persistent stochastic analyses. Our technique utilizes frequency-time maps of GW strain cross power between two spatially separated terrestrial GW detectors. The application of our cross power statistic to searches for GW transients is framed as a pattern recognition problem, and we discuss several pattern-recognition techniques. We demonstrate these techniques by recovering simulated GW signals in simulated detector noise. We also recover environmental noise artifacts, thereby demonstrating a novel technique for the identification of such artifacts in GW interferometers. We compare the efficiency of this framework to other techniques such as matched filtering
Combined fluorescence lifetime and surface topographical imaging of biological tissue
In this work a combined fluorescence lifetime and surface topographical imaging system is demonstrated. Based around a 126 × 192 time resolved single photon avalanche diode (SPAD) array operating in time correlated single-photon counting (TCSPC) mode, both the fluorescence lifetime and time of flight (ToF) can be calculated on a pixel by pixel basis. Initial tests on fluorescent samples show it is able to provide 4 mm resolution in distance and 0.4 ns resolution in lifetime. This combined modality has potential biomedical applications such as surgical guidance, endoscopy and diagnostic imaging. The system is demonstrated on both ovine and human pulmonary tissue samples, where it offers excellent fluorescence lifetime contrast whilst also giving a measure of the distance to the sample surfac
- …